FUSELESS LOAD FEEDER DIRECT START, 400V AC, SZ. S0, 20...25A, 15KW, 24 V DC WITH DIODE ASSEMBLY SNAPPED ONTO FRONT SCREW CONNECTION FOR 600MM BUSBAR SYSTEMS, TYPE OF COORDINATION 2, IQ = 150KA (ALSO SATISFIES TYPE OF COORDINATION 1) 1NC + 1NO (CONTACTOR)
FUSELESS LOAD FEEDER DIRECT START, 400V AC, SIZE S0, 27...32A, 15KW, 24 V DC WITH DIODE COMBINATION INSERTED ON FRONT SIDE SCREW TERMINAL FOR MOUNTING ONTO DIN RAIL, TYPE OF COORDINATION 2, IQ = 150KA ALSO FULFILLS TYPE OF COORDINATION 1) 1OE + 1NO (CONTACTOR)
FUSELESS LOAD FEEDER DIRECT START, 400V AC, SZ. S0, 27...32A, 15KW, 24 V DC WITH DIODE ASSEMBLY SNAPPED ONTO FRONT SCREW CONNECTION FOR 600MM BUSBAR SYSTEMS, TYPE OF COORDINATION 2, IQ = 150KA (ALSO SATISFIES TYPE OF COORDINATION 1) 1NC + 1NO (CONTACTOR)
LOAD FEEDER FUSELESS DIRECT START, AC 400V, SZ S00 11. . .16A, DC 24V SCREW CONNECTION FOR RAIL-MOUNTING, TYPE OF COORDINATION 1, IQ = 150KA 1NO (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER)
DIRECT START, AC 400V, SZ. S0, 14 ...20A, 100V 50HZ / 100 ... 110V 60HZ SCREW CONNECTION FOR DIN RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO+1NC (CONTACTOR) COIL WITH RC ELEMENT ON FRONT INSERTED (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
DIRECT START, AC 400V, SZ. S0, 14 ...20A, 100V 50HZ / 100 ... 110V 60HZ SPRING-LOADED CONNECTION FOR DIN RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO+1NC (CONTACTOR) COIL WITH RC ELEMENT ON FRONT INSERTED (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
DIRECT START, AC 400V, SZ. S0, 17 ...22A, 100V 50HZ / 100 ... 110V 60HZ SCREW CONNECTION FOR DIN RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO+1NC (CONTACTOR) COIL WITH RC ELEMENT ON FRONT INSERTED (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
DIRECT START, AC 400V, SZ. S0, 17 ...22A, 100V 50HZ / 100 ... 110V 60HZ SPRING-LOADED CONNECTION FOR DIN RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO+1NC (CONTACTOR) COIL WITH RC ELEMENT ON FRONT INSERTED (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
DIRECT START, AC 400V, SZ. S0, 20 ...25A, 100V 50HZ / 100 ... 110V 60HZ SCREW CONNECTION FOR DIN RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO+1NC (CONTACTOR) COIL WITH RC ELEMENT ON FRONT INSERTED (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
DIRECT START, AC 400V, SZ. S0, 20 ...25A, 100V 50HZ / 100 ... 110V 60HZ SPRING-LOADED CONNECTION FOR DIN RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO+1NC (CONTACTOR) COIL WITH RC ELEMENT ON FRONT INSERTED (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
DIRECT START, AC 400V, SZ. S0, 27 ...32A, 100V 50HZ / 100 ... 110V 60HZ SCREW CONNECTION FOR DIN RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO+1NC (CONTACTOR) COIL WITH RC ELEMENT ON FRONT INSERTED (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
DIRECT START, AC 400V, SZ. S0, 27 ...32A, 100V 50HZ / 100 ... 110V 60HZ SPRING-LOADED CONNECTION FOR DIN RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO+1NC (CONTACTOR) COIL WITH RC ELEMENT ON FRONT INSERTED (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
DIRECT START, AC 400V, SZ. S0, 23 ...28A, 100V 50HZ / 100 ... 110V 60HZ SCREW CONNECTION FOR DIN RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO+1NC (CONTACTOR) COIL WITH RC ELEMENT ON FRONT INSERTED (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
DIRECT START, AC 400V, SZ. S0, 23 ...28A, 100V 50HZ / 100 ... 110V 60HZ SPRING-LOADED CONNECTION FOR DIN RAIL MOUNTING, TYPE OF ASSIGNMENT 2,IQ = 150KA (ALSO FULFILLS TYPE OF ASSIGNMENT 1) 1NO+1NC (CONTACTOR) COIL WITH RC ELEMENT ON FRONT INSERTED (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 0.14...0.20 A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM 1NC (CONTACTOR) ADAPTER LENGTH 200MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 0.18...0.25 A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM 1NC (CONTACTOR) ADAPTER LENGTH 200MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 0.22...0.32A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM 1NC (CONTACTOR) ADAPTER LENGTH 200MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 0.28...0.40A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM 1NC (CONTACTOR) ADAPTER LENGTH 200MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 0.35...0.50 A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM 1NC (CONTACTOR) ADAPTER LENGTH 200MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 0.45...0.63 A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM 1NC (CONTACTOR) ADAPTER LENGTH 200MM