Выберите подкатегорию:
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ S00 0.55 TO 0.80 A, 1.5 KW, 24 V DC SCREW TERMINAL FOR STANDARD RAIL MOUNTING, TYPE OF COORDINATION 1, IQ = 50 KA
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ S00, 0.55 TO 0.80 A, 1.5 KW, 24 V DC SCREW TERMINAL ON MOUNTING RAIL ADAPTER TYPE OF COORDINATION 1, IQ = 50K A
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 0.55...0.80A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM 1NC (CONTACTOR) ADAPTER LENGTH 200MM
LOAD FEEDER FUSELESS REVERSING DUTY, AC 400V, SZ S00, 0.7. . .1A, DC 24V SCREW TERMINAL FOR RAIL-MOUNTING, TYPE OF COORDINATION 1, IQ = 150KA WITH SOLID-STATE CONTACTOR
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 0.70...1.00A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 0.90...1.25 A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 1.10...1.60A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 1.40...2.00 A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 1.80...2.50 A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 2.20...3.20A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 2.80...4.00A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM (ALSO FULFILLS COORD. TYPE 1) TYPE OF COORD. 2, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V DC, SZ. S00 3.50...5.00 A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60MM TYPE OF COORD. 1,IQ = 150KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 4.50...6.30 A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM TYPE OF COORD. 1,IQ = 150KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, AC 400V, S00 5.5. . .8A, DC 24V SCREW TERMINAL FOR RAIL MOUNTING, TYPE OF ASSIGNMENT 1,IQ = 150KA 1NC (CONTACTOR)
FUSELESS LOAD FEEDER REVERSING OPERATION, AC 400V, S00 5.5. . .8A, DC 24V SCREW TERMINAL FOR BUSBAR SYSTEMS 60MM TYPE OF ASSIGNMENT 1,IQ = 150KA 1NC (CONTACTOR)
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V DC, SZ. S00 5.50...8.00 A 3 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM TYPE OF COORD. 1,IQ = 150KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 7.00...10.0 A 4 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM TYPE OF COORD. 1, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 9.00...12.5 A 5.5 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM TYPE OF COORD. 1, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ. S00 11.0...16.0 A 7.5 KW, 24 V DC SPRING-LOADED TERMINAL FOR BUSBAR SYSTEMS 60 MM TYPE OF COORD. 1, IQ = 150 KA 1NC (CONTACTOR) ADAPTER LENGTH 200 MM
LOAD FEEDER FUSELESS REVERSING OPERATION, AC 400V, SZ. S00, 1.1...1.6A, 24 V DC SCREW CONNECTION FOR MOUNTING ON STANDARD RAIL, TYPE OF COORDINATION 2,IQ = 150KA ALSO FULFILLS TYPE OF COORDINATION 1) 1NC (CONTACTOR) 1NO+1NC (CIRCUIT BREAKER, TRANSVERSE)