LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANGK-250MM-42 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC411, SIZE 250 4/2 POLES 45/55 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANGK-250MM-64 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC411, SIZE 250 6/4 POLES 28/40 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANGK-250MM-84 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC411, SIZE 250 8/4 POLES 32/46 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANGK-250MM-86 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC411, SIZE 250 8/6 POLES 24/32 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANLK-250MM-02 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR, EXT. COOLED II 3G EX NA IIC T3 GC IP55, IC416, SIZE 250, IE2 2 POLE 55 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANLK-250MM-04 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR, EXT. COOLED II 3G EX NA IIC T3 GC IP55, IC416, SIZE 250, IE2 4 POLE 55 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANLK-250MM-06 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR, EXT. COOLED II 3G EX NA IIC T3 GC IP55, IC416, SIZE 250, IE2 6 POLE 37 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANLK-250MM-08 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR, EXT. COOLED II 3G EX NA IIC T3 GC IP55, IC416, SIZE 250 8 POLE 30 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANLK-250MM-10 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR, EXT. COOLED II 3G EX NA IIC T3 GC IP55, IC416, SIZE 250 10 POLE 22 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANLK-250MM-12 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR, EXT. COOLED II 3G EX NA IIC T3 GC IP55, IC416, SIZE 250 12 POLE 18,5 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANWK-250EF-02 CONVERTER FEED, NORMAL INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC71W, SIZE 250 2-POLE 132 KW AT 50HZ NOT ACCORDING TO EG 640/2009
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANWK-250FA-04 CONVERTER FEED, NORMAL INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC71W, SIZE 250 4-POLE 132 KW AT 50HZ NOT ACCORDING TO EG 640/2009
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANGK-250MM-02 CONVERTER FEED, SPECIAL INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC411, SIZE 250, IE2 2 POLES 55 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANGK-250MM-04 CONVERTER FEED, SPECIAL INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC411, SIZE 250, IE2 4 POLES 55 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANGK-250MM-06 CONVERTER FEED, SPECIAL INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC411, SIZE 250, IE2 6 POLES 37 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANGK-250MM-08 CONVERTER FEED, SPECIAL INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC411, SIZE 250 8 POLES 30 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANGK-250MM-10 CONVERTER FEED, SPECIAL INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC411, SIZE 250 10 POLES 22 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANGK-250MM-12 CONVERTER FEED, SPECIAL INSUL. STANDARD ROTOR II 3G EX NA IIC T3 GC IP55, IC411, SIZE 250 12 POLES 18,5 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANLK-250MM-02 CONVERTER FEED, SPECIAL INSUL. STANDARD ROTOR, EXT. COOLED II 3G EX NA IIC T3 GC IP55, IC416, SIZE 250, IE2 2 POLE 55 KW AT 50HZ
LV SQUIRREL-CAGE MOT., CHEMSTAR LOHER TYPE: ANLK-250MM-04 CONVERTER FEED, SPECIAL INSUL. STANDARD ROTOR, EXT. COOLED II 3G EX NA IIC T3 GC IP55, IC416, SIZE 250, IE2 4 POLE 55 KW AT 50HZ