LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LN-06; 6 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION 1000KW 50HZ / 1120KW 60HZ
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LN-08; 8 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION 900KW 50HZ / 1000KW 60HZ
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LN-10; 10 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LN-12; 12 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LN-14; 14 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LN-16; 16 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LN-06; 6 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION PREFORMED COIL
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LN-08; 8 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION PREFORMED COIL
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNUL-500LN-06; 6 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC416 FORCED VENTILATION (AXIALLY) MAINS OPERATION PREFORMED COIL
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNUL-500LN-08; 8 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC416 FORCED VENTILATION (AXIALLY) MAINS OPERATION PREFORMED COIL
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LN-06; 6 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED INVERTER OPERATION PREFORMED COIL
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LN-08; 8 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED INVERTER OPERATION PREFORMED COIL
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNUL-500LN-06; 6 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC416 FORCED VENTILATION (AXIALLY) INVERTER OPERATION PREFORMED COIL
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNUL-500LN-08; 8 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC416 FORCED VENTILATION (AXIALLY) INVERTER OPERATION PREFORMED COIL
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LX-04; 4 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION 1400KW 50HZ
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LX-06; 6 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION 1120KW 50HZ / 1250KW 60HZ
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LX-08; 8 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION 950KW 50HZ / 1050KW 60HZ
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LX-10; 10 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LX-12; 12 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION
LOW-VOLTAGE MOTOR; SQUIRREL- CAGE ROTOR; LOHER-TYPE: DNSL-500LX-14; 14 POLE; IP56; II 2G EX D(E) IIB T4 GB COOLING IC411 SELF VENTILATED MAINS OPERATION STANDARD INSULATION